Shark 270 | Shark 250 | Shark 200 | Shark 100 | Shark 100B | Shark 50 | Shark 50B | Shark 200S | Shark 100S | MP200 | ST40 |
---|---|---|---|---|---|---|---|---|---|---|
Typical Applications
Utility/Industrial Revenue Metering
|
Typical Applications
Utility/Industrial
|
Typical Applications
Utility/Industrial
|
Typical Applications
Utility/Industrial
|
Typical Applications
Commercial Energy Management
|
Typical Applications
Industrial Panel Boards
|
Typical Applications
Commercial Energy Management
|
Typical Applications
Commercial Submetering
|
Typical Applications
Commercial Submetering
|
Typical Applications
Multi-circuit Submetering
|
Typical Applications
Commercial/Industrial Submetering
|
Physical Features
9S; 36S; 45S; 9A; SWB3
Install Without Cutting Panel |
Physical Features
ANSI C39.1 4 in. round or IEC 96 mm DIN square form
Install Without Cutting Panel |
Physical Features
ANSI C39.1 4 in. round or IEC 96 mm DIN square form
Install Without Cutting Panel |
Physical Features
ANSI C39.1 4 in. round or IEC 96 mm DIN square form
Install Without Cutting Panel |
Physical Features
ANSI C39.1 4 in. round or IEC 96 mm DIN square form
Install Without Cutting Panel |
Physical Features
ANSI C39.1 4 in. round or IEC 96 mm DIN square form
Install Without Cutting Panel |
Physical Features
ANSI C39.1 4 in. round or IEC 96 mm DIN square form
Install Without Cutting Panel |
Physical Features
Wall Mountable
|
Physical Features
Wall Mountable
|
Physical Features
Multi-circuit Design
|
Physical Features
Compact Size; DIN-rail Mounting
|
Display Options
Integrated
LCD Programmable |
Display Options
Integrated
LED |
Display Options
Integrated
LED |
Display Options
Integrated
LED |
Display Options
Integrated
LED |
Display Options
Integrated
LED |
Display Options
Integrated
LED |
Display Options
Integrated
LED |
Display Options
Integrated
LED |
Display Options
Color Touchscreen
LCD Remote |
Display Options
Integrated
LED |
Basic Measurements and Accuracy
% Energy Accuracy - 0.1
ANSI C12.20 Accuracy Class - 0.1 CL Certified Current Class - Class 2 or Class 10 Current Pickup - Class 20 (5 mA); Class 2 (1 mA) Extended Frequency Measurement Accuracy +/- 0.007 Hz Frequency Range - (45 - 65) Hz Number of 3 Phase Circuits - 1 Number of Current Inputs - 3 Sampling Rate - Over 400 samples/cycle Voltage Pickup - 10 V AC; programmable Voltage Range Line to Line - (20 - 721) V |
Basic Measurements and Accuracy
% Energy Accuracy - 0.1
ANSI C12.20 Accuracy Class - 0.1 CL Certified Current Class - Class 2 or Class 10 Current Pickup - Class 10 (5 mA); Class 2 (1 mA) Extended Frequency Measurement Accuracy +/- 0.007 Hz Frequency Range - (45 - 65) Hz Number of Current Inputs - 3 Sampling Rate - Over 400 samples/cycle Voltage Pickup - 10 V AC; programmable Voltage Range Line to Line - Absolute Range (0-721) V |
Basic Measurements and Accuracy
% Energy Accuracy - 0.2
ANSI C12.20 Accuracy Class - 0.2 CL Certified Current Class - Class 2 or Class 10 Current Pickup - Class 10 (5 mA); Class 2 (1 mA) Extended Frequency Measurement Accuracy +/- 0.007 Hz Frequency Range - (45 - 65) Hz Number of 3 Phase Circuits - 1 Number of Current Inputs - 3 Sampling Rate - Over 400 samples/cycle Voltage Pickup - 10 V AC; programmable Voltage Range Line to Line - Absolute Range (0-721) V |
Basic Measurements and Accuracy
% Energy Accuracy - 0.2
ANSI C12.20 Accuracy Class - 0.2 CL Current Class - Class 2 or Class 10 Current Pickup - Class 10 (5 mA); Class 2 (1 mA) Frequency Range - (45 - 65) Hz Number of 3 Phase Circuits - 1 Number of Current Inputs - 3 Sampling Rate - Over 400 samples/cycle Voltage Pickup - 20 V AC Voltage Range Line to Line - Absolute Range (0-721) V |
Basic Measurements and Accuracy
% Energy Accuracy - 0.2
ANSI C12.20 Accuracy Class - 0.2 CL Current Class - Class 2 or Class 10 Current Pickup - 5 mA Current Pickup - Class 10 (5 mA); Class 2 (1 mA) Frequency Range - (45 - 65) Hz Number of 3 Phase Circuits - 1 Number of Current Inputs - 3 Sampling Rate - Over 400 samples/cycle Voltage Pickup - 20 V AC Voltage Range Line to Line - Absolute Range (0-721) V |
Basic Measurements and Accuracy
% Energy Accuracy - 0.5
ANSI C12.20 Accuracy Class - 0.5 CL Current Class - Class 10 Current Pickup - 5 mA Frequency Range - (45 - 65) Hz Number of 3 Phase Circuits - 1 Number of Current Inputs - 3 Sampling Rate - Over 400 samples/cycle Voltage Pickup - 20 V AC Voltage Range Line to Line - (20 - 721) V |
Basic Measurements and Accuracy
% Energy Accuracy - 0.5
ANSI C12.20 Accuracy Class - 0.5 CL Current Class - Class 10 Current Pickup - 5 mA Frequency Range - (45 - 65) Hz Number of 3 Phase Circuits - 1 Number of Current Inputs - 3 Sampling Rate - Over 400 samples/cycle Voltage Pickup - 20 V AC Voltage Range Line to Line - Absolute Range (0-721) V |
Basic Measurements and Accuracy
% Energy Accuracy - 0.2
ANSI C12.20 Accuracy Class - 0.2 CL Certified Current Class - Class 2 or Class 10 Current Pickup - Class 10 (5 mA); Class 2 (1 mA) Extended Frequency Measurement Accuracy +/- 0.007 Hz Frequency Range - (45 - 65) Hz Number of 3 Phase Circuits - 1 Number of Current Inputs - 3 Overload Conditions - 100 A; 10 Sec Sampling Rate - Over 400 samples/cycle Voltage Pickup - 10 V AC Voltage Range Line to Line - (0 - 721) V |
Basic Measurements and Accuracy
% Energy Accuracy - 0.2
ANSI C12.20 Accuracy Class - 0.2 CL Current Class - Class 2 or Class 10 Current Pickup - Class 10 (5 mA); Class 2 (1 mA) Frequency Range - (45 - 65) Hz Number of 3 Phase Circuits - 1 Number of Current Inputs - 3 Overload Conditions - 100 A; 10 Sec Sampling Rate - Over 400 samples/cycle Voltage Pickup - 10 V AC Voltage Range Line to Line - (0 - 721) V |
Basic Measurements and Accuracy
% Energy Accuracy - 0.5
ANSI C12.20 Accuracy Class - 0.5 CL Current Class - Class 2 or Class 10 Current Pickup - Class 10 (5 mA); Class 2 (1 mA) Frequency Range - (45 - 65) Hz Number of 3 Phase Circuits - 8 Number of Current Inputs - 24 Sampling Rate - Over 400 samples/cycle Voltage Pickup - 20 V AC Voltage Range Line to Line - Absolute Range (0-721) V |
Basic Measurements and Accuracy
% Energy Accuracy - 0.2
ANSI C12.20 Accuracy Class - 0.2 CL Current Class - Class 2 or Class 10 Current Pickup - Class 10 (5 mA); Class 2 (1 mA) Frequency Range - (45 - 65) Hz mV CTs - 0.333 V or Rogowski Coil CTs Number of 3 Phase Circuits - 1 Number of Current Inputs - 3 Sampling Rate - Over 400 samples/cycle Voltage Pickup - 20 V AC Voltage Range Line to Line - Absolute Range (0-721) V |
Advanced Revenue Measurements
Accuracy Test Pulse
CT and PT Compensation Energy Presets Test Mode Time of Use Transformer and Line Loss Compensation |
Advanced Revenue Measurements
Accuracy Test Pulse
CT and PT Compensation Energy Presets Test Mode Time of Use Transformer and Line Loss Compensation |
Advanced Revenue Measurements
Accuracy Test Pulse
CT and PT Compensation Transformer and Line Loss Compensation |
Advanced Revenue Measurements
Accuracy Test Pulse
|
Advanced Revenue Measurements
Accuracy Test Pulse
|
Advanced Revenue Measurements
|
Advanced Revenue Measurements
Accuracy Test Pulse
|
Advanced Revenue Measurements
Accuracy Test Pulse
CT and PT Compensation Transformer and Line Loss Compensation |
Advanced Revenue Measurements
Accuracy Test Pulse
|
Advanced Revenue Measurements
Accuracy Test Pulse
|
Advanced Revenue Measurements
Accuracy Test Pulse
CT and PT Compensation Transformer and Line Loss Compensation |
Logging
I/O Log
Limit Log Memory (Max.) - 128 MB PQ Log Programmable Historical Logs - 6 Stored Waveform Events before FIFO (Max.) - 128 System Events Log |
Logging
I/O Log
Limit Log Memory (Max.) - 128 MB PQ Log Programmable Historical Logs - 6 Stored Waveform Events before FIFO (Max.) - 128 System Events Log |
Logging
I/O Log
Limit Log Memory (Max.) - 4 MB PQ Log Programmable Historical Logs - 3 Stored Waveform Events before FIFO (Max.) - 170 System Events Log |
Logging
|
Logging
|
Logging
|
Logging
|
Logging
Limit Log Memory (Max.) - 2 MB Programmable Historical Logs - 3
System Events Log
|
Logging
|
Logging
I/O Log Limit Log Memory (Max.) - 32 MB Programmable Historical Logs
- 2 System Events Log
|
Logging
Limit Log Memory - Extensive Memory Programmable Historical Logs - 3
Stored Waveform Events before FIFO (Max.) - 128 System Events Log
|
Power Quality
CBEMA and SEMI F47 Monitoring
COMTRADE Waveforms Harmonics - Up to 40th Order K-Factor Programmable Alarm Alerts Symmetrical Components and Imbalance (Voltage and Current) TDD THD Waveform Sampling Rate - 512 samples/cycle |
Power Quality
CBEMA and SEMI F47 Monitoring
COMTRADE Waveforms Harmonics - Up to 40th Order K-Factor Programmable Alarm Alerts Symmetrical Components and Imbalance (Voltage and Current) TDD THD Waveform Sampling Rate - 512 samples/cycle |
Power Quality
CBEMA and SEMI F47 Monitoring
COMTRADE Waveforms Harmonics - Up to 40th Order K-Factor Programmable Alarm Alerts Symmetrical Components and Imbalance (Voltage and Current) TDD THD Waveform Sampling Rate - 512 samples/cycle |
Power Quality
Harmonics - 7th order (current); 3rd order (voltage)
Programmable Alarm Alerts THD |
Power Quality
Harmonics - 7th order (current); 3rd order (voltage)
Programmable Alarm Alerts THD |
Power Quality
|
Power Quality
|
Power Quality
Programmable Alarm Alerts
|
Power Quality
Harmonics - 7th order (current); 3rd order (voltage)
Programmable Alarm Alerts THD |
Power Quality
Programmable Alarm Alerts
|
Power Quality
CBEMA and SEMI F47 Monitoring
Harmonics - 40th Order Programmable Alarm Alerts THD Waveform Sampling Rate - 512 samples/cycle |
Other
Custom Modbus Map
Embedded HTML5-based Web Server End of Interval Pulse Field Upgrades (V-Switches) Surge Suppression Technology |
Other
Embedded Web Server
End of Interval Pulse Field Upgrades (V-Switches) |
Other
Embedded Web Server
End of Interval Pulse Field Upgrades (V-Switches) |
Other
Field Upgrades (V-Switches)
|
Other
Embedded Web Server
|
Other
Field Upgrades (V-Switches)
|
Other
Embedded Web Server
|
Other
|
Other
Field Upgrades (V-Switches)
|
Other
Field Upgrades (V-Switches)
|
Other
Field Upgrades (V-Switches)
|
I/O
Analog Outputs (Max.) - 8
Digital Inputs (Max.) - 4 KYZ Pulse Outputs (Max.) - 9 Pulse Inputs (Max.) - 8 Relay Outputs (Max.) - 4 |
I/O
Analog Outputs (Max.) - 8
Digital Inputs (Max.) - 4 KYZ Pulse Outputs (Max.) - 9 Pulse Inputs (Max.) - 8 Relay Outputs (Max.) - 4 |
I/O
Analog Outputs (Max.) - 8
Digital Inputs (Max.) - 4 KYZ Pulse Outputs (Max.) - 9 Pulse Inputs (Max.) - 8 Relay Outputs (Max.) - 4 |
I/O
KYZ Pulse Outputs (Max.) - 1
|
I/O
KYZ Pulse Outputs (Max.) - 1
|
I/O
KYZ Pulse Outputs (Max.) - 1
|
I/O
|
I/O
|
I/O
|
I/O
KYZ Inputs (Max.) - 4
Relay Outputs (Max.) - 2 |
I/O
|
Time Synchronization
DNP Time Sync
IRIG-B Line Frequency Sync NTP RTC Clock Accuracy - Better than 15 seconds per month |
Time Synchronization
DNP Time Sync
Line Frequency Sync NTP RTC Clock Accuracy - 15 seconds per month over the temperature range is the “worst case” scenario - 6 seconds per month is typical at -15 °C to +25 °C. |
Time Synchronization
Line Frequency Sync
NTP RTC Clock Accuracy - Max. +/-2 seconds per day at 25 °C |
Time Synchronization
|
Time Synchronization
|
Time Synchronization
|
Time Synchronization
|
Time Synchronization
Line Frequency Sync
|
Time Synchronization
|
Time Synchronization
RTC Clock Accuracy - ±3.5 ppm max. (±0.3024 second/day) over the
rated temperature range
|
Time Synchronization
Line Frequency Sync
RTC Clock Accuracy - Max. +/-2 seconds per day at 25 °C |
Cyber Security Features
Allow/Block Lists
Digital Firmware Signature Encrypted User IDs and Passwords Ethernet Card Encryption; Configurable Firewalls; and Digital Firmware Signature NERC / CIP Utility Security Protocol Compliance Password Fail Timeouts Password Protection Physical Seals Programmable Port Control Programmable Seal Switch Role Based Authorization |
Cyber Security Features
Allow/Block Lists
Encrypted User IDs and Passwords NERC / CIP Utility Security Protocol Compliance Password Fail Timeouts Password Protection Programmable Port Control Programmable Seal Switch Role Based Authorization |
Cyber Security Features
Exclusive Client Feature
Password Protection Programmable Port Control |
Cyber Security Features
Password Protection
|
Cyber Security Features
Password Protection
|
Cyber Security Features
Password Protection
|
Cyber Security Features
Password Protection
|
Cyber Security Features
Password Protection
|
Cyber Security Features
Password Protection
|
Cyber Security Features
Password Protection
|
Cyber Security Features
Password Protection
|
Communication
2 Separately Addressable Ethernet Ports
ANSI Optical Port Data Rates - 100 ms and 1 second DNP3 Level 2 Email on Alarm IEC 61850 IPV4 IPV6 Modbus ASCII Modbus RTU Modbus TCP/IP MV90 Support Number of Communication Ports (Max.) - 4 Number of Simultaneous Communication Connections (Max.) - 24 RJ45 Ethernet - 2 RS232 - 2 RS485 - 3 Underglass 4G Cellular Modem |
Communication
2 Separately Addressable Ethernet Ports
Data Rates - 100 ms and 1 second DNP3 Level 2 Email on Alarm Fiber Optic Ethernet IEC 61850 IPV4 IPV6 IrDA Port Modbus ASCII Modbus RTU Modbus TCP/IP MV90 Support Number of Communication Ports (Max.) - 4 Number of Simultaneous Communication Connections (Max .) - 24 RJ45 Ethernet - 2 RS232 - 2 RS485 - 1 USB - 1 |
Communication
2 Separately Addressable Ethernet Ports
Data Rates - Watts; VAR; and VA; 100 ms; All other parameters; 1 second DNP3 Email on Alarm Fiber Optic Ethernet IEC 61850 IPV4 IrDA Port Modbus ASCII Modbus RTU Modbus TCP/IP MV90 Support Number of Communication Ports (Max.) - 4 Number of Simultaneous Communication Connections (Max.) - 24 RJ45 Ethernet - 2 RS485 - 1 |
Communication
Data Rates - Watts; VAR; and VA; 100 ms; All other parameters; 1
second
DNP3 IPV4 IrDA Port Modbus ASCII Modbus RTU Modbus TCP/IP Number of Communication Ports (Max.) - 2 RS485 - 1 |
Communication
BACnet/IP
Data Rates - Watts; VAR; and VA; 100 ms; All other parameters; 1 second IPV4 IrDA Port Modbus ASCII Modbus RTU Modbus TCP/IP Number of Communication Ports (Max.) - 2 RJ45 Ethernet - 1 |
Communication
Data Rates - 1 second
IPV4 Modbus ASCII Modbus RTU Number of Communication Ports (Max.) - 1 Number of Simultaneous Communication Connections - 1 RS485 - 1 |
Communication
BACnet MS/TP
Data Rates - all parameters every 60 cycles IPV4 Modbus RTU Modbus TCP/IP Number of Communication Ports (Max.) - 2 RJ45 Ethernet - 1 RS485 - 1 |
Communication
Data Rates - 100 ms and 1 second
DNP3 IPV4 IrDA Port Modbus ASCII Modbus RTU Modbus TCP/IP Number of Communication Ports (Max.) - 3 Number of Simultaneous Communication Connections - 2 RJ45 Ethernet - 1 RS485 - 1 WiFi - 802.11 WiFi |
Communication
Data Rates - 100 ms and 1 second
DNP3 IPV4 IrDA Port Modbus ASCII Modbus RTU Modbus TCP/IP Number of Communication Ports (Max.) - 3 Number of Simultaneous Communication Connections - 2 RJ45 Ethernet - 1 RS485 - 1 WiFi - 802.11 WiFi |
Communication
Data Rates - 1 second
IPV4 Modbus ASCII Modbus RTU Modbus TCP/IP Number of Communication Ports (Max.) - 4 Number of Simultaneous Communication Connections - 3 RJ45 Ethernet - 1 RS485 - 2 USB - 1 WiFi - 802.11 WiFi |
Communication
BACnet/IP
Data Rates - 100 ms and 1 second DNP3 IPV4 Modbus ASCII Modbus RTU Modbus TCP/IP MV90 Support Number of Communication Ports (Max.) - 2 Number of Simultaneous Communication Connections - 3 RJ45 Ethernet - 1 RS485 - 1 USB - 1 |
Standards Conformity
ANSI C12.18
ANSI C12.20 0.1 CL CE Marked FCC Part 15; Class B IEC 61557-12 IEC 62053-22 Class - 0.2S Certified IEC 62053-23 Reactive Energy - Class 2 Certified IEEE C37.90.1 IEEE C62.41 REACH/RoHS Compliance |
Standards Conformity
ANSI C12.20 0.1 CL
CE Marked IEC 62053-22 Class - 0.2S IEC 62053-23 Reactive Energy - Class 2 IEEE C37.90.1 IEEE C62.41 REACH/RoHS Compliance UL 61010-1 |
Standards Conformity
ANSI C12.20 0.2 CL
ANSI C12.41 CE Marked EN 61000-6-2 EN 61000-6-4 FCC Part 15; Class B IEC 61850 Certification IEC 62053-22 Class - 0.2S Certified IEC 62053-23 Reactive Energy - Class 2 IEEE C37.90.1 IEEE C62.41 NY State Approved for Residential Metering REACH/RoHS Compliance UL 61010-1 |
Standards Conformity
ANSI C12.20 0.2 CL
CE Marked IEC 62053-22 Class - 0.2S IEC 62053-23 Reactive Energy - Class 2 IEEE C37.90.1 IEEE C62.41 REACH/RoHS Compliance UL 61010-1 |
Standards Conformity
CE Marked
IEC 62053-22 Class - 0.2S IEC 62053-23 Reactive Energy - Class 2 IEEE C37.90.1 IEEE C62.41 REACH/RoHS Compliance UL 61010-1 |
Standards Conformity
ANSI C12.20 0.5 CL
CE Marked IEC 62053-22 Class - 0.5S Certified IEEE C37.90.1 IEEE C62.41 REACH/RoHS Compliance UL 61010-1 |
Standards Conformity
CE Marked
IEC 62053-22 Class - 0.5S Certified IEEE C37.90.1 IEEE C62.41 REACH/RoHS Compliance UL 61010-1 |
Standards Conformity
ANSI C12.20 0.2 CL and C12.1 Certified
ANSI C62.41 CE Marked ERM: Wideband transmission system operating in the 2.4GHz ISM band using wideband modulation techniques. V1.6.1 (WiFi Module) Information technology equipment-Safety-part 1: General requirements: 2001 FCC Part 15; Class B IEC 62053-22 Class - 0.2S Certified IEC 62053-23 Reactive Energy - Class 2 Ed. 1 IEEE C37.90.1 IEEE C62.41 REACH/RoHS Compliance UL 61010-1 |
Standards Conformity
ANSI C12.20 0.2 CL
CE Marked ERM: Wideband transmission system operating in the 2.4GHz ISM band using wideband modulation techniques. V1.6.1 (WiFi Module) Information technology equipment-Safety-part 1: General requirements: 2001 IEC 62053-22 Class - 0.2S IEC 62053-23 Reactive Energy - Class 2 Ed. 1 IEEE C37.90.1 IEEE C62.41 REACH/RoHS Compliance UL 61010-1 |
Standards Conformity
ANSI C12.20 0.5 CL
CE Marked ERM: Wideband transmission system operating in the 2.4GHz ISM band using wideband modulation techniques. V1.6.1 (WiFi Module) Information technology equipment-Safety-part 1: General requirements: 2001 IEC 62053-22 Class - 0.5S REACH/RoHS Compliance UL 61010-1 |
Standards Conformity
ANSI C12.20 0.2 CL
CE Marked IEC 62053-22 Class - 0.2S REACH/RoHS Compliance UL 61010-1 |
Power Supply and Environmental
Humidity - Up to 95% RH non-condensing
IP Rating Meter - IP51 Power Supply Range - Dependent on voltage form; see brochure Temperature - Storage: (-40 to +85) °C; Meter Operating: (-40 to +70) °C; Display Operating: (-30 to +60) °C |
Power Supply and Environmental
Humidity - Up to 95% RH non-condensing
IP Rating Display - IP30 NEMA Rating - NEMA 12 Power Supply Range - Option 1 - (90-265) V AC or (100-370) V DC; Option 2 (18-60) V DC Temperature - Storage: (-20 to +70) °C; Operating: (-20 to +70) °C |
Power Supply and Environmental
Humidity - Up to 95% RH non-condensing
IP Rating Display - IP30 NEMA Rating - NEMA 12 Power Supply Range - Option 1 - (90-265) V AC or (100-370) V DC; Option 2 (18-60) V DC Temperature - Storage: (-20 to +70) °C; Operating: (-20 to +70) °C |
Power Supply and Environmental
Humidity - Up to 95% RH non-condensing
IP Rating Display - IP30 NEMA Rating - NEMA 12 Power Supply Range - Option 1 - (90-265) V AC or (100-370) V DC; Option 2 (18-60) V DC Storage: (-20 to +70) °C; Operating: (-20 to +70) °C |
Power Supply and Environmental
Humidity - Up to 95% RH non-condensing
IP Rating Display - IP30 NEMA Rating - NEMA 12 Power Supply Range - Option 1 - (90-265) V AC; Option 2 (18-60) V DC Temperature - Storage: (-20 to +70) °C; Operating: (-20 to +70) °C |
Power Supply and Environmental
Humidity - Up to 95% RH non-condensing
IP Rating Display - IP30 NEMA Rating - NEMA 12 Power Supply Range - (90-265) V AC Storage: (-20 to +70) °C; Operating: (-20 to +70) °C |
Power Supply and Environmental
Humidity - Up to 95% RH non-condensing
IP Rating Display - IP30 NEMA Rating - NEMA 12 Power Supply Range - (90-265) V AC Storage: (-20 to +70) °C; Operating: (-20 to +70) °C |
Power Supply and Environmental
Humidity - Up to 95% RH non-condensing
IP Rating Display - IP30 Power Supply Range - (90 to 400) V AC or (100 to 370) V DC; Universal AC/DC Supply Temperature - Storage: (-20 to +70) °C /(-4 to +158) °F; Operating: (-20 to +70) °C /(-4 to +158) °F |
Power Supply and Environmental
Humidity - Up to 95% RH non-condensing
IP Rating Display - IP30 Power Supply Range - (90 to 400) V AC or (100 to 370) V DC; Universal AC/DC Supply Temperature - Storage: (-20 to +70) °C /(-4 to +158) °F; Operating: (-20 to +70) °C /(-4 to +158) °F |
Power Supply and Environmental
Humidity - Up to 95% RH non-condensing
Power Supply Range - (90-300) V AC @ 50/60 Hz Temperature - Storage: (-20 to +70) °C / (-4 to +158) °F; Operating: (-20 to +60) °C / (-4 to +140) °F |
Power Supply and Environmental
Humidity - Up to 95% RH non-condensing
IP Rating Display - IP30 Power Supply Range - (90-300) V AC @ 50/60 Hz Temperature - Storage: (-20 to +70) °C; Operating: (-20 to +70) °C *;* UL certified to °65 |
Dimensions
Case Design - Plastic
Keystone Connectors for Communication and I/O Overall Size: Socket Form: H7" x W6.96" x D8.75"; Switchboard Form (SWB3): H10.37" x W7.85" x D8.97" |
Dimensions
Case Design - Plastic
DIN-rail Mounted - Transducer Version Overall Size - H4.85" x W4.85" x D4.25" in. |
Dimensions
Case Design - Plastic
DIN-rail Mounted - Transducer Version Overall Size - H4.85" x W4.85" x D4.25" in. |
Dimensions
Case Design - Plastic
DIN-rail Mounted - Transducer Version Overall Size - H4.85" x W4.85" x D4.25" in. |
Dimensions
Case Design - Plastic
DIN-rail Mounted - Transducer Version Overall Size - H4.85" x W4.85" x D4.25" in. |
Dimensions
Case Design - Plastic
Overall Size - H4.85" x W4.85" x D4.25" in. |
Dimensions
Case Design - Plastic
DIN-rail Mounted - Transducer Version Overall Size - H4.85" x W4.85" x D4.25" in. |
Dimensions
Case Design - Plastic
Overall Size - H7.90" x W7.53" x D3.11" |
Dimensions
Case Design - Plastic
Overall Size - H7.90" x W7.53" x D3.11" |
Dimensions
Case Design - Metal
Overall Size - H7.60" x W11.28" x D3.18" |
Dimensions
Case Design - Plastic
Overall Size - H4.60" x W4.77" x D2.44" |