Nexus 1500+ Nexus 1450 Nexus 1252 Nexus 1272 Nexus 1262
Typical Applications
Utility/Industrial - Power Quality Measurement
Typical Applications
Utility/Industrial - Power Quality Measurement
Typical Applications
Utility/Industrial - Power Quality Measurement
Typical Applications
Utility/Industrial Revenue Metering & Power Quality
Typical Applications
Utility/Industrial Revenue Metering
Physical Features
Mount vertically or horizontally
Physical Features
Display Mounts into Existing Knockouts

Install Without Cutting Panel

Transducer with Remote Display
Physical Features
Display Mounts into Existing Knockouts

Install Without Cutting Panel

Transducer with Remote Display
Physical Features
Install Without Cutting Panel
Physical Features
Install Without Cutting Panel
Display Options
Color Touchscreen

Integrated

LCD
Display Options
Color Touchscreen

LCD

Remote
Display Options
LED

Remote
Display Options
Integrated

LCD

Programmable
Display Options
Integrated

LCD

Programmable
Basic Measurements and Accuracy
% Energy Accuracy - 0.06

ANSI C12.20 Accuracy Class - 0.1 CL Certified

Current Class - Class 2 or Class 20

Current Fault Recording Peak - 80 A/Class 20

Current Pickup 5 mA/1 mA

Frequency Range - (42.5 - 69.9) Hz

Number of 3 Phase Circuits - 1

Number of Current Inputs - 4

Overload Conditions - 100 A; 10 Sec

Sampling Rate - Over 400 samples/cycle

Voltage Pickup - 5 V

Voltage Range Line to Line - (10 - 600) V AC

Basic Measurements and Accuracy
% Energy Accuracy - 0.06

ANSI C12.20 Accuracy Class - 0.1 CL

Current Class - Class 20 and 2 in one configuration

Current Fault Recording Peak - 80 A

Current Pickup - 1 mA

Frequency Range - Nominal (42.5 - 69.9) Hz; Wide Band (20 - 500) Hz

Number of 3 Phase Circuits - 1

Number of Current Inputs - 4

Overload Conditions - 100 A; 10 Sec

Sampling Rate - Over 400 samples/cycle

Voltage Pickup - 5 V

Voltage Range Line to Line - (20 - 720) V AC

Basic Measurements and Accuracy
% Energy Accuracy - 0.06

ANSI C12.20 Accuracy Class - 0.2 CL

Current Class - Class 10; 2; or 0.5 (2 and 0.5 are special order)

Current Fault Recording Peak - 60 A

Current Pickup 5 mA/1 mA

Frequency Range - (20 - 65) Hz

Number of 3 Phase Circuits - 1

Number of Current Inputs - 4

Overload Conditions - 100 A; 10 Sec

Sampling Rate - Over 400 samples/cycle

Voltage Range Line to Line - 300 V (Standard; for use with PTs); 600 V (Option G)

Basic Measurements and Accuracy
% Energy Accuracy - 0.06

ANSI C12.20 Accuracy Class - 0.2 CL

Current Class - Class 20; 10; or 2

Current Pickup 5 mA/1 mA

Overload Conditions - 100 A; 10 Sec

Sampling Rate - Over 400 samples/cycle

Voltage Pickup - 2 V

Voltage Range Line to Line - Option S: 600; Option LV: 120 V

Basic Measurements and Accuracy
% Energy Accuracy - 0.06

ANSI C12.20 Accuracy Class - 0.2 CL

Current Class - Class 20; 10; or 2

Current Pickup 5 mA/1 mA

Number of Current Inputs - 2 or 3 depending on form

Overload Conditions - 100 A; 10 Sec

Sampling Rate - Over 400 samples/cycle

Voltage Pickup - 2 V

Voltage Range Line to Line - Option S: 600; Option LV: 120 V

Advanced Revenue Measurements
Accuracy Test Pulse - 2

CT and PT Compensation

Energy Presets

Test Mode

Time of Use

Transformer and Line Loss Compensation
Advanced Revenue Measurements
TAccuracy Test Pulse - 2

Time of Use

Transformer and Line Loss Compensation
Advanced Revenue Measurements
Accuracy Test Pulse

CT and PT Compensation

Time of Use

Transformer and Line Loss Compensation
Advanced Revenue Measurements
Accuracy Test Pulse

CT and PT Compensation

Energy Presets

Test Mode

Time of Use

Transformer and Line Loss Compensation
Advanced Revenue Measurements
Accuracy Test Pulse

CT and PT Compensation

Energy Presets

Test Mode

Time of Use

Transformer and Line Loss Compensation
Logging
I/O Log

Limit Log

Memory (Max.) - 4 GB

PQ Log

Programmable Historical Logs - 8

Stored Waveform Events before FIFO (Max.) - 3199

System Events Log
Logging
Core Log with 172 Automatic Parameters

I/O Log

Limit Log

Memory (Max.) - 1.2 GB

PQ Log

Programmable Historical Logs - 8

Stored Waveform Events before FIFO (Max.) - 5461

System Events Log
Logging
I/O Log

Limit Log

Memory (Max.) - 4 MB

PQ Log

Programmable Historical Logs - 2

Stored Waveform Events before FIFO (Max.) - 95

System Events Log
Logging
I/O Log

Limit Log

Memory (Max.) - 4 MB

PQ Log

Programmable Historical Logs - 2

Stored Waveform Events before FIFO (Max.) - 95

System Events Log
Logging
I/O Log

Limit Log

Memory (Max.) - 2 MB

Programmable Historical Logs - 2

System Events Log
Power Quality
CBEMA and SEMI F47 Monitoring

COMTRADE Waveforms

EN 50160 PQ Reporting

Flicker

Harmonics - 127th Order

IEC 61000-4-30 Class A Ed. 3 Certified

K-Factor

Programmable Alarm Alerts

Symmetrical Components and Imbalance (Voltage and Current)

TDD

THD

Transient Recording - 50 MHz

Waveform Sampling Rate - 1024 samples/cycle
Power Quality
CBEMA and SEMI F47 Monitoring

EN 50160 PQ Reporting

Flicker

Harmonics - 127th Order

IEC 61000-4-30 Class A Ed. 3 Certified

IEEE 519

K-Factor

Programmable Alarm Alerts

Symmetrical Components and Imbalance (Voltage and Current)

TDD

THD

Waveform Sampling Rate - 1024 samples/cycle
Power Quality
CBEMA and SEMI F47 Monitoring

COMTRADE Waveforms

EN 50160 PQ Reporting

Flicker

Harmonics - 255th Order

IEC 61000-4-30 Class A Ed. 3

K-Factor

Programmable Alarm Alerts

Symmetrical Components and Imbalance (Voltage and Current)

TDD

THD

Waveform Sampling Rate - 512 samples/cycle
Power Quality
CBEMA and SEMI F47 Monitoring

COMTRADE Waveforms

EN 50160 PQ Reporting

Flicker

Harmonics - 255th Order

IEC 61000-4-30 Class A Ed. 3

K-Factor

Programmable Alarm Alerts

Symmetrical Components and Imbalance (Voltage and Current)

TDD

THD

Waveform Sampling Rate - 512 samples/cycle
Power Quality
COMTRADE Waveforms

Harmonics - 128th Order

Programmable Alarm Alerts

Symmetrical Components and Imbalance (Voltage and Current)

THD
Other
Custom Modbus Map

Embedded Web Server

End of Interval Pulse

Field Upgrades (V-Switches)

Phasor Measurement Unit (PMU) - P/M

Relay Logic
Other
Custom Modbus Map

Embedded HTML5-based Web Server with Waveform Analysis

End of Interval Pulse

Field Upgrades (V-Switches)

Relay Logic
Other
Custom Modbus Map

Embedded Web Server

End of Interval Pulse

Field Upgrades (V-Switches)

Relay Logic
Other
Custom Modbus Map

Embedded Web Server

End of Interval Pulse

Field Upgrades (V-Switches)

Relay Logic
Other
Custom Modbus Map

Embedded Web Server

End of Interval Pulse

Field Upgrades (V-Switches)

Relay Logic
I/O
Analog Inputs (Max.) - 16

Analog Outputs (Max.) - 16

Digital Inputs (Max.) - 40

KYZ Pulse Outputs (Max.) - 8

Relay Outputs (Max.) - 28

Relay Outputs (Max.) - 8
I/O
Analog Inputs (Max.) - 32

Analog Outputs (Max.) - 16

Digital Inputs (Max.) - 40

KYZ Pulse Outputs (Max.) - 18

Relay Outputs (Max.) - 16
I/O
Analog Inputs (Max.) - 32

Analog Outputs (Max.) - 32

Digital Inputs (Max.) - 40

KYZ Pulse Outputs (Max.) - 16

Relay Outputs (Max.) - 16
I/O
Analog Inputs (Max.) - 32

Analog Outputs (Max.) - 32

Digital Inputs (Max.) - 40

KYZ Pulse Outputs (Max.) - 20

Relay Outputs (Max.) - 16
I/O
Analog Inputs (Max.) - 32

Analog Outputs (Max.) - 32

Digital Inputs (Max.) - 40

KYZ Pulse Outputs (Max.) - 20

Relay Outputs (Max.) - 16
Time Synchronization
DNP Time Sync

IRIG-B

Line Frequency Sync

NTP

PTP IEEE-1588

RTC Clock Accuracy - 3.5 ppm
Time Synchronization
DNP Time Sync

IRIG-B

Line Frequency Sync

NTP

RTC Clock Accuracy - 20 ppm
Time Synchronization
DNP Time Sync

IRIG-B

Line Frequency Sync

NTP

RTC Clock Accuracy - 20 ppm
Time Synchronization
DNP Time Sync

IRIG-B

Line Frequency Sync

RTC Clock Accuracy - 1 second per Month
Time Synchronization
DNP Time Sync

IRIG-B

Line Frequency Sync

RTC Clock Accuracy - 1 second per Month
Cyber Security Features
128 Bit AES Encryption

Digital Firmware Signature

Encrypted User IDs and Passwords

NERC / CIP Utility Security Protocol Compliance

Password Fail Timeouts

Password Protection

Physical Seals

Programmable Port Control

Programmable Seal Switch

Role Based Authorization
Cyber Security Features
128 Bit AES Encryption

Digital Firmware Signature

Encrypted User IDs and Passwords

NERC / CIP Utility Security Protocol Compliance

Password Fail Timeouts

Password Protection

Physical Seals

Programmable Port Control

Role Based Authorization
Cyber Security Features
Password Protection

Physical Seals

Programmable Port Control

Programmable Seal Switch
Cyber Security Features
Password Protection

Physical Seals

Programmable Port Control

Programmable Seal Switch
Cyber Security Features
Password Protection

Physical Seals

Programmable Port Control

Programmable Seal Switch
Communication
2 Separately Addressable Ethernet Ports

ANSI Optical Port

Data Rates - 1 second; 2 to 20; 1 cycle

DHCP

DNP3 Level 2

Email on Alarm

Ethernet Gateway

Fiber Optic Ethernet

GE EGD

IEC 61850

IEC 61850 GOOSE

IPV4

Modbus ASCII

Modbus RTU

Modbus TCP/IP

MV90 Support

Number of Communication Ports (Max.) - 6

RJ45 Ethernet - 2

RS485 - 2

RTU Master

SNMP

USB - 1
Communication
2 Separately Addressable Ethernet Ports

Data Rates - 1 second; 2 to 20; 1 cycle

DHCP

DNP3 Level 2

Email on Alarm

Fiber Optic Ethernet

GE EGD

IEC 61850

IEC 61850 GOOSE

IPV4

IPV6

Modbus ASCII

Modbus RTU

Modbus TCP/IP

MV90 Support

Number of Communication Ports (Max.) - 6

Number of Simultaneous Communication Connections - 6

RJ45 Ethernet - 1

RS232 - 1

RS485 - 4

RTU Master
Communication
Data Rates - 1 cycle; 1 second; 200 ms

DHCP

DNP3 Level 2

Email on Alarm

Ethernet Gateway

GE EGD

IPV4

Modbus ASCII

Modbus RTU

Modbus TCP/IP

MV90 Support

Number of Communication Ports (Max.) - 4

Number of Simultaneous Communication Connections - 4

RJ45 Ethernet - 1

RS232 - 1

RS485 - 4

RTU Master
Communication
ANSI Optical Port

Data Rates - 1 cycle; 1 second; 200 ms

DHCP

DNP3 Level 2

Email on Alarm

Ethernet Gateway

GE EGD

IPV4

Modbus ASCII

Modbus RTU

Modbus TCP/IP

MV90 Support

Number of Communication Ports (Max.) - 5

Number of Simultaneous Communication Connections - 5

RJ45 Ethernet - 1

RS485 - 2

RTU Master
Communication
ANSI Optical Port

Data Rates - 1 cycle; 1 second; 200 ms

DHCP

DNP3 Level 2

Email on Alarm

Ethernet Gateway

GE EGD

IPV4

Modbus ASCII

Modbus RTU

Modbus TCP/IP

MV90 Support

Number of Communication Ports (Max.) - 5

Number of Simultaneous Communication Connections - 5

RJ45 Ethernet - 1

RS485 - 2

RTU Master
Standards Conformity
ANSI C12.20 0.1 CL

ANSI C62.41

CE Marked - Certified

CISPR 11 Ed. 5.1

CISPR 22 Class A

FCC Part 15; Class B

IEC 61000-4-15

IEC 61000-4-30 Class A Ed. 3 Certified

IEC 61000-6-2

IEC 61000-6-4

IEC 61850 Certification

IEC 62053-22 Class - 0.2S Certified

IEC 62053-23 Reactive Energy Ed. 1

IEC 62586-2

IEEE C37.118 - PMU

REACH/RoHS Compliance

UL 61010-1
Standards Conformity
ANSI C12.20 0.1 CL

CE Marked

CISPR 11

EN/IEC 61000-3-2 Class A

EN/IEC 61000-3-3

ICES 001 2006

IEC 61000-4-15

IEC 61000-4-30 Class A Ed. 3 Certified

IEC 62053-22 Class - 0.2S

IEC 62053-23 Reactive Energy - Class 2 Ed. 1

IEC 62586-2

IEEE 519

REACH/RoHS Compliance

UL 61010-1
Standards Conformity
ANSI C12.20 0.2 CL

CE Marked

IEC 62053-22 Class - 0.2S

UL 61010-1
Standards Conformity
ANSI C12.20 0.2 CL and C12.1

IEC 60687 Certified

IEC 62053-11

IEC 62053-22 Class - 0.2S Certified

IS 14967
Standards Conformity
ANSI C12.20 0.2 CL and C12.1

IEC 60687 Certified

IEC 62053-11

IEC 62053-22 Class - 0.2S Certified

IS 14967
Power Supply and Environmental
Humidity - Up to 95% RH non-condensing

IP Rating Display - IP30

Power Supply Range - Option 1 (100–240) V AC @ 50/60 Hz or (100-240) V DC; Option 2 (18-60) V DC (24-48 V DC Systems); Option 3 (100-240) V AC @ 50/60 Hz

Temperature - Operating: (-20 to +70) °C/(-4 to +158) °F
Power Supply and Environmental
Humidity - Up to 95% RH non-condensing

IP Rating Display - IP30

IP Rating Meter - IP65

Power Supply Range - Option 1 (96-276) V @ 50/60 Hz or DC; Option 2 (18-60) V DC

Temperature - Operating: (-25 to +70) °C/(-32 to +158) °F
Power Supply and Environmental
Humidity - Up to 95% RH non-condensing

Power Supply Range - Option 1 120 V AC/DC (-20%) to 230 V AC (+20%); Option 2 24 V DC (-20%) to 48 V DC (+20%)

Temperature - Operating: (-40 to +70) °C/(-40 to +158) °F
Power Supply and Environmental
Humidity - Up to 95% RH non-condensing

Power Supply Range - Option 1 - (102 to 270) V AC/DC @50/60 Hz; Option 2 - (18 to 60) V DC

Temperature - Operating: (-40 to +85) °C/(-40 to +185) °F; Display: (-20 to +60) °C/(-4 to +140) °F
Power Supply and Environmental
Humidity - Up to 95% RH non-condensing

Power Supply Range - Option 1 - (102 to 270) V AC/DC @50/60 Hz; Option 2 - (18 to 60) V DC

Temperature - Operating: (-40 to +85) °C/(-40 to +185) °F; Display: (-20 to +60) °C/(-4 to +140) °F
Dimensions
Case Design - Plastic

Overall Size: 10.74 x 6.74 x 6.91 in/27.28 x 17.12 x 17.55 cm
Dimensions
Case Design - Metal

Overall Size - 7.25 x 10.70 x 3.74 in/18.41 x 27.19 x 9.51 cm
Dimensions
Case Design - Metal

Overall Size - 3.4H x 7.3W x 10.5L in/8.6 x 18.5 x 26.6 cm
Dimensions
Case Design - Metal/Plastic

Legacy Switchboard: 16” W x 14” D x 11” H/ 40.64 cm x 35.56 cm x 28 cm

NEMA 4X Rated Cover for Switchboard

Overall Size - Socket: 13” W x 10” D x 11” H/33.02 cm x 25.40 cm x 28 cm

Switchboard (SWB3): H10.37" x W7.85" x D8.97"
Dimensions
Case Design - Metal/Plastic

Legacy Switchboard: 16” W x 14” D x 11” H/ 40.64 cm x 35.56 cm x 28 cm

NEMA 4X Rated Cover for Switchboard

Overall Size - Socket: 13” W x 10” D x 11” H/33.02 cm x 25.40 cm x 28 cm

Switchboard (SWB3): H10.37" x W7.85" x D8.97"