Nexus 1500+ | Nexus 1450 | Nexus 1252 | Nexus 1272 | Nexus 1262 |
---|---|---|---|---|
Typical Applications
Utility/Industrial - Power Quality Measurement
|
Typical Applications
Utility/Industrial - Power Quality Measurement
|
Typical Applications
Utility/Industrial - Power Quality Measurement
|
Typical Applications
Utility/Industrial Revenue Metering & Power Quality
|
Typical Applications
Utility/Industrial Revenue Metering
|
Physical Features
Mount vertically or horizontally
|
Physical Features
Display Mounts into Existing Knockouts
Install Without Cutting Panel Transducer with Remote Display |
Physical Features
Display Mounts into Existing Knockouts
Install Without Cutting Panel Transducer with Remote Display |
Physical Features
Install Without Cutting Panel
|
Physical Features
Install Without Cutting Panel
|
Display Options
Color Touchscreen
Integrated LCD |
Display Options
Color Touchscreen
LCD Remote |
Display Options
LED
Remote |
Display Options
Integrated
LCD Programmable |
Display Options
Integrated
LCD Programmable |
Basic Measurements and Accuracy
% Energy Accuracy - 0.06
ANSI C12.20 Accuracy Class - 0.1 CL Certified Current Class - Class 2 or Class 20 Current Fault Recording Peak - 80 A/Class 20 Current Pickup 5 mA/1 mA Frequency Range - (42.5 - 69.9) Hz Number of 3 Phase Circuits - 1 Number of Current Inputs - 4 Overload Conditions - 100 A; 10 Sec Sampling Rate - Over 400 samples/cycle Voltage Pickup - 5 V Voltage Range Line to Line - (10 - 600) V AC |
Basic Measurements and Accuracy
% Energy Accuracy - 0.06
ANSI C12.20 Accuracy Class - 0.1 CL Current Class - Class 20 and 2 in one configuration Current Fault Recording Peak - 80 A Current Pickup - 1 mA Frequency Range - Nominal (42.5 - 69.9) Hz; Wide Band (20 - 500) Hz Number of 3 Phase Circuits - 1 Number of Current Inputs - 4 Overload Conditions - 100 A; 10 Sec Sampling Rate - Over 400 samples/cycle Voltage Pickup - 5 V Voltage Range Line to Line - (20 - 720) V AC |
Basic Measurements and Accuracy
% Energy Accuracy - 0.06
ANSI C12.20 Accuracy Class - 0.2 CL Current Class - Class 10; 2; or 0.5 (2 and 0.5 are special order) Current Fault Recording Peak - 60 A Current Pickup 5 mA/1 mA Frequency Range - (20 - 65) Hz Number of 3 Phase Circuits - 1 Number of Current Inputs - 4 Overload Conditions - 100 A; 10 Sec Sampling Rate - Over 400 samples/cycle Voltage Range Line to Line - 300 V (Standard; for use with PTs); 600 V (Option G) |
Basic Measurements and Accuracy
% Energy Accuracy - 0.06
ANSI C12.20 Accuracy Class - 0.2 CL Current Class - Class 20; 10; or 2 Current Pickup 5 mA/1 mA Overload Conditions - 100 A; 10 Sec Sampling Rate - Over 400 samples/cycle Voltage Pickup - 2 V Voltage Range Line to Line - Option S: 600; Option LV: 120 V |
Basic Measurements and Accuracy
% Energy Accuracy - 0.06
ANSI C12.20 Accuracy Class - 0.2 CL Current Class - Class 20; 10; or 2 Current Pickup 5 mA/1 mA Number of Current Inputs - 2 or 3 depending on form Overload Conditions - 100 A; 10 Sec Sampling Rate - Over 400 samples/cycle Voltage Pickup - 2 V Voltage Range Line to Line - Option S: 600; Option LV: 120 V |
Advanced Revenue Measurements
Accuracy Test Pulse - 2
CT and PT Compensation Energy Presets Test Mode Time of Use Transformer and Line Loss Compensation |
Advanced Revenue Measurements
TAccuracy Test Pulse - 2
Time of Use Transformer and Line Loss Compensation |
Advanced Revenue Measurements
Accuracy Test Pulse
CT and PT Compensation Time of Use Transformer and Line Loss Compensation |
Advanced Revenue Measurements
Accuracy Test Pulse
CT and PT Compensation Energy Presets Test Mode Time of Use Transformer and Line Loss Compensation |
Advanced Revenue Measurements
Accuracy Test Pulse
CT and PT Compensation Energy Presets Test Mode Time of Use Transformer and Line Loss Compensation |
Logging
I/O Log
Limit Log Memory (Max.) - 4 GB PQ Log Programmable Historical Logs - 8 Stored Waveform Events before FIFO (Max.) - 3199 System Events Log |
Logging
Core Log with 172 Automatic Parameters
I/O Log Limit Log Memory (Max.) - 1.2 GB PQ Log Programmable Historical Logs - 8 Stored Waveform Events before FIFO (Max.) - 5461 System Events Log |
Logging
I/O Log
Limit Log Memory (Max.) - 4 MB PQ Log Programmable Historical Logs - 2 Stored Waveform Events before FIFO (Max.) - 95 System Events Log |
Logging
I/O Log
Limit Log Memory (Max.) - 4 MB PQ Log Programmable Historical Logs - 2 Stored Waveform Events before FIFO (Max.) - 95 System Events Log |
Logging
I/O Log
Limit Log Memory (Max.) - 2 MB Programmable Historical Logs - 2 System Events Log |
Power Quality
CBEMA and SEMI F47 Monitoring
COMTRADE Waveforms EN 50160 PQ Reporting Flicker Harmonics - 127th Order IEC 61000-4-30 Class A Ed. 3 Certified K-Factor Programmable Alarm Alerts Symmetrical Components and Imbalance (Voltage and Current) TDD THD Transient Recording - 50 MHz Waveform Sampling Rate - 1024 samples/cycle |
Power Quality
CBEMA and SEMI F47 Monitoring
EN 50160 PQ Reporting Flicker Harmonics - 127th Order IEC 61000-4-30 Class A Ed. 3 Certified IEEE 519 K-Factor Programmable Alarm Alerts Symmetrical Components and Imbalance (Voltage and Current) TDD THD Waveform Sampling Rate - 1024 samples/cycle |
Power Quality
CBEMA and SEMI F47 Monitoring
COMTRADE Waveforms EN 50160 PQ Reporting Flicker Harmonics - 255th Order IEC 61000-4-30 Class A Ed. 3 K-Factor Programmable Alarm Alerts Symmetrical Components and Imbalance (Voltage and Current) TDD THD Waveform Sampling Rate - 512 samples/cycle |
Power Quality
CBEMA and SEMI F47 Monitoring
COMTRADE Waveforms EN 50160 PQ Reporting Flicker Harmonics - 255th Order IEC 61000-4-30 Class A Ed. 3 K-Factor Programmable Alarm Alerts Symmetrical Components and Imbalance (Voltage and Current) TDD THD Waveform Sampling Rate - 512 samples/cycle |
Power Quality
COMTRADE Waveforms
Harmonics - 128th Order Programmable Alarm Alerts Symmetrical Components and Imbalance (Voltage and Current) THD |
Other
Custom Modbus Map
Embedded Web Server End of Interval Pulse Field Upgrades (V-Switches) Phasor Measurement Unit (PMU) - P/M Relay Logic |
Other
Custom Modbus Map
Embedded HTML5-based Web Server with Waveform Analysis End of Interval Pulse Field Upgrades (V-Switches) Relay Logic |
Other
Custom Modbus Map
Embedded Web Server End of Interval Pulse Field Upgrades (V-Switches) Relay Logic |
Other
Custom Modbus Map
Embedded Web Server End of Interval Pulse Field Upgrades (V-Switches) Relay Logic |
Other
Custom Modbus Map
Embedded Web Server End of Interval Pulse Field Upgrades (V-Switches) Relay Logic |
I/O
Analog Inputs (Max.) - 16
Analog Outputs (Max.) - 16 Digital Inputs (Max.) - 40 KYZ Pulse Outputs (Max.) - 8 Relay Outputs (Max.) - 28 Relay Outputs (Max.) - 8 |
I/O
Analog Inputs (Max.) - 32
Analog Outputs (Max.) - 16 Digital Inputs (Max.) - 40 KYZ Pulse Outputs (Max.) - 18 Relay Outputs (Max.) - 16 |
I/O
Analog Inputs (Max.) - 32
Analog Outputs (Max.) - 32 Digital Inputs (Max.) - 40 KYZ Pulse Outputs (Max.) - 16 Relay Outputs (Max.) - 16 |
I/O
Analog Inputs (Max.) - 32
Analog Outputs (Max.) - 32 Digital Inputs (Max.) - 40 KYZ Pulse Outputs (Max.) - 20 Relay Outputs (Max.) - 16 |
I/O
Analog Inputs (Max.) - 32
Analog Outputs (Max.) - 32 Digital Inputs (Max.) - 40 KYZ Pulse Outputs (Max.) - 20 Relay Outputs (Max.) - 16 |
Time Synchronization
DNP Time Sync
IRIG-B Line Frequency Sync NTP PTP IEEE-1588 RTC Clock Accuracy - 3.5 ppm |
Time Synchronization
DNP Time Sync
IRIG-B Line Frequency Sync NTP RTC Clock Accuracy - 20 ppm |
Time Synchronization
DNP Time Sync
IRIG-B Line Frequency Sync NTP RTC Clock Accuracy - 20 ppm |
Time Synchronization
DNP Time Sync
IRIG-B Line Frequency Sync RTC Clock Accuracy - 1 second per Month |
Time Synchronization
DNP Time Sync
IRIG-B Line Frequency Sync RTC Clock Accuracy - 1 second per Month |
Cyber Security Features
128 Bit AES Encryption
Digital Firmware Signature Encrypted User IDs and Passwords NERC / CIP Utility Security Protocol Compliance Password Fail Timeouts Password Protection Physical Seals Programmable Port Control Programmable Seal Switch Role Based Authorization |
Cyber Security Features
128 Bit AES Encryption
Digital Firmware Signature Encrypted User IDs and Passwords NERC / CIP Utility Security Protocol Compliance Password Fail Timeouts Password Protection Physical Seals Programmable Port Control Role Based Authorization |
Cyber Security Features
Password Protection
Physical Seals Programmable Port Control Programmable Seal Switch |
Cyber Security Features
Password Protection
Physical Seals Programmable Port Control Programmable Seal Switch |
Cyber Security Features
Password Protection
Physical Seals Programmable Port Control Programmable Seal Switch |
Communication
2 Separately Addressable Ethernet Ports
ANSI Optical Port Data Rates - 1 second; 2 to 20; 1 cycle DHCP DNP3 Level 2 Email on Alarm Ethernet Gateway Fiber Optic Ethernet GE EGD IEC 61850 IEC 61850 GOOSE IPV4 Modbus ASCII Modbus RTU Modbus TCP/IP MV90 Support Number of Communication Ports (Max.) - 6 RJ45 Ethernet - 2 RS485 - 2 RTU Master SNMP USB - 1 |
Communication
2 Separately Addressable Ethernet Ports
Data Rates - 1 second; 2 to 20; 1 cycle DHCP DNP3 Level 2 Email on Alarm Fiber Optic Ethernet GE EGD IEC 61850 IEC 61850 GOOSE IPV4 IPV6 Modbus ASCII Modbus RTU Modbus TCP/IP MV90 Support Number of Communication Ports (Max.) - 6 Number of Simultaneous Communication Connections - 6 RJ45 Ethernet - 1 RS232 - 1 RS485 - 4 RTU Master |
Communication
Data Rates - 1 cycle; 1 second; 200 ms
DHCP DNP3 Level 2 Email on Alarm Ethernet Gateway GE EGD IPV4 Modbus ASCII Modbus RTU Modbus TCP/IP MV90 Support Number of Communication Ports (Max.) - 4 Number of Simultaneous Communication Connections - 4 RJ45 Ethernet - 1 RS232 - 1 RS485 - 4 RTU Master |
Communication
ANSI Optical Port
Data Rates - 1 cycle; 1 second; 200 ms DHCP DNP3 Level 2 Email on Alarm Ethernet Gateway GE EGD IPV4 Modbus ASCII Modbus RTU Modbus TCP/IP MV90 Support Number of Communication Ports (Max.) - 5 Number of Simultaneous Communication Connections - 5 RJ45 Ethernet - 1 RS485 - 2 RTU Master |
Communication
ANSI Optical Port
Data Rates - 1 cycle; 1 second; 200 ms DHCP DNP3 Level 2 Email on Alarm Ethernet Gateway GE EGD IPV4 Modbus ASCII Modbus RTU Modbus TCP/IP MV90 Support Number of Communication Ports (Max.) - 5 Number of Simultaneous Communication Connections - 5 RJ45 Ethernet - 1 RS485 - 2 RTU Master |
Standards Conformity
ANSI C12.20 0.1 CL
ANSI C62.41 CE Marked - Certified CISPR 11 Ed. 5.1 CISPR 22 Class A FCC Part 15; Class B IEC 61000-4-15 IEC 61000-4-30 Class A Ed. 3 Certified IEC 61000-6-2 IEC 61000-6-4 IEC 61850 Certification IEC 62053-22 Class - 0.2S Certified IEC 62053-23 Reactive Energy Ed. 1 IEC 62586-2 IEEE C37.118 - PMU REACH/RoHS Compliance UL 61010-1 |
Standards Conformity
ANSI C12.20 0.1 CL
CE Marked CISPR 11 EN/IEC 61000-3-2 Class A EN/IEC 61000-3-3 ICES 001 2006 IEC 61000-4-15 IEC 61000-4-30 Class A Ed. 3 Certified IEC 62053-22 Class - 0.2S IEC 62053-23 Reactive Energy - Class 2 Ed. 1 IEC 62586-2 IEEE 519 REACH/RoHS Compliance UL 61010-1 |
Standards Conformity
ANSI C12.20 0.2 CL
CE Marked IEC 62053-22 Class - 0.2S UL 61010-1 |
Standards Conformity
ANSI C12.20 0.2 CL and C12.1
IEC 60687 Certified IEC 62053-11 IEC 62053-22 Class - 0.2S Certified IS 14967 |
Standards Conformity
ANSI C12.20 0.2 CL and C12.1
IEC 60687 Certified IEC 62053-11 IEC 62053-22 Class - 0.2S Certified IS 14967 |
Power Supply and Environmental
Humidity - Up to 95% RH non-condensing
IP Rating Display - IP30 Power Supply Range - Option 1 (100–240) V AC @ 50/60 Hz or (100-240) V DC; Option 2 (18-60) V DC (24-48 V DC Systems); Option 3 (100-240) V AC @ 50/60 Hz Temperature - Operating: (-20 to +70) °C/(-4 to +158) °F |
Power Supply and Environmental
Humidity - Up to 95% RH non-condensing
IP Rating Display - IP30 IP Rating Meter - IP65 Power Supply Range - Option 1 (96-276) V @ 50/60 Hz or DC; Option 2 (18-60) V DC Temperature - Operating: (-25 to +70) °C/(-32 to +158) °F |
Power Supply and Environmental
Humidity - Up to 95% RH non-condensing
Power Supply Range - Option 1 120 V AC/DC (-20%) to 230 V AC (+20%); Option 2 24 V DC (-20%) to 48 V DC (+20%) Temperature - Operating: (-40 to +70) °C/(-40 to +158) °F |
Power Supply and Environmental
Humidity - Up to 95% RH non-condensing
Power Supply Range - Option 1 - (102 to 270) V AC/DC @50/60 Hz; Option 2 - (18 to 60) V DC Temperature - Operating: (-40 to +85) °C/(-40 to +185) °F; Display: (-20 to +60) °C/(-4 to +140) °F |
Power Supply and Environmental
Humidity - Up to 95% RH non-condensing
Power Supply Range - Option 1 - (102 to 270) V AC/DC @50/60 Hz; Option 2 - (18 to 60) V DC Temperature - Operating: (-40 to +85) °C/(-40 to +185) °F; Display: (-20 to +60) °C/(-4 to +140) °F |
Dimensions
Case Design - Plastic
Overall Size: 10.74 x 6.74 x 6.91 in/27.28 x 17.12 x 17.55 cm |
Dimensions
Case Design - Metal
Overall Size - 7.25 x 10.70 x 3.74 in/18.41 x 27.19 x 9.51 cm |
Dimensions
Case Design - Metal
Overall Size - 3.4H x 7.3W x 10.5L in/8.6 x 18.5 x 26.6 cm |
Dimensions
Case Design - Metal/Plastic
Legacy Switchboard: 16” W x 14” D x 11” H/ 40.64 cm x 35.56 cm x 28 cm NEMA 4X Rated Cover for Switchboard Overall Size - Socket: 13” W x 10” D x 11” H/33.02 cm x 25.40 cm x 28 cm Switchboard (SWB3): H10.37" x W7.85" x D8.97" |
Dimensions
Case Design - Metal/Plastic
Legacy Switchboard: 16” W x 14” D x 11” H/ 40.64 cm x 35.56 cm x 28 cm NEMA 4X Rated Cover for Switchboard Overall Size - Socket: 13” W x 10” D x 11” H/33.02 cm x 25.40 cm x 28 cm Switchboard (SWB3): H10.37" x W7.85" x D8.97" |